Cisco2970 资料收集
版权声明:原创作品,允许转载,转载时请务必以超链接形式标明文章 原始出处 、作者信息和本声明。否则将追究法律责任。http://3layer.blog.51cto.com/57448/34814 |
Switch#show version Cisco IOS Software, C2970 Software (C2970-LANBASE-M), Version 12.2(25)SEB4, RELEASE SOFTWARE (fc1) Copyright (c) 1986-2005 by Cisco Systems, Inc. Compiled Tue 30-Aug-05 12:19 by yenanh ROM: Bootstrap program is C2970 boot loader
BOOTLDR: C2970 Boot Loader (C2970-HBOOT-M) Version 12.1(14r)EA1a, RELEASE SOFTWARE (fc1) Switch uptime is 14 minutes
System returned to ROM by power-on System image file is "flash:c2970-lanbase-mz.122-25.SEB4/c2970-lanbase-mz.122-25.SEB4.bin" cisco WS-C2970G-24TS-E (PowerPC405) processor (revision L0) with 118784K/12280K bytes of memory.
Processor board ID CAT0947Z1ZS Last reset from power-on 1 Virtual Ethernet interface 28 Gigabit Ethernet interfaces The password-recovery mechanism is enabled. 512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 00:16:46:A4:D9:80 Motherboard assembly number : 73-9095-07 Power supply part number : 341-0045-01 Motherboard serial number : CAT09470WD5 Power supply serial number : LIT09420BZD Model revision number : L0 Motherboard revision number : A0 Model number : WS-C2970G-24TS-E System serial number : CAT0947Z1ZS Top Assembly Part Number : 800-24261-05 Top Assembly Revision Number : B0 Hardware Board Revision Number : 0x02 Switch Ports Model SW Version SW Image ------ ----- ----- ---------- ---------- * 1 28 WS-C2970G-24TS-E 12.2(25)SEB4 C2970-LANBASE-M Configuration register is 0xF Switch# show vlan
VLAN Name Status Ports
---- -------------------------------- --------- ------------------------------- 1 default active Gi0/25, Gi0/26, Gi0/27, Gi0/28 2 VLAN0002 active Gi0/17, Gi0/18, Gi0/19, Gi0/20 Gi0/21, Gi0/22, Gi0/23, Gi0/24 3 VLAN0003 active Gi0/1, Gi0/2, Gi0/3, Gi0/4 Gi0/5, Gi0/6, Gi0/7, Gi0/8 Gi0/9, Gi0/10, Gi0/11, Gi0/12 Gi0/13, Gi0/14, Gi0/15, Gi0/16 11 hpc active 12 office active 13 mega active 14 info active 15 edu active 16 chinanet active 17 arp active 18 building_8_1 active 19 office2 active 20 buiding_10_4 active 21 nc-test active 22 test active 1002 fddi-default act/unsup VLAN Name Status Ports
---- -------------------------------- --------- ------------------------------- 1003 trcrf-default act/unsup 1004 fddinet-default act/unsup 1005 trbrf-default act/unsup VLAN Type SAID MTU Parent RingNo BridgeNo Stp BrdgMode Trans1 Trans2
---- ----- ---------- ----- ------ ------ -------- ---- -------- ------ ------ 1 enet 100001 1500 - - - - - 0 0 2 enet 100002 1500 - - - - - 0 0 3 enet 100003 1500 - - - - - 0 0 11 enet 100011 1500 - - - - - 0 0 12 enet 100012 1500 - - - - - 0 0 13 enet 100013 1500 - - - - - 0 0 14 enet 100014 1500 - - - - - 0 0 15 enet 100015 1500 - - - - - 0 0 16 enet 100016 1500 - - - - - 0 0 17 enet 100017 1500 - - - - - 0 0 18 enet 100018 1500 - - - - - 0 0 19 enet 100019 1500 - - - - - 0 0 20 enet 100020 1500 - - - - - 0 0 21 enet 100021 1500 - - - - - 0 0 22 enet 100022 1500 - - - - - 0 0 1002 fddi 101002 1500 - - - - - 0 0 1003 trcrf 101003 4472 1005 3276 - - srb 0 0 VLAN Type SAID MTU Parent RingNo BridgeNo Stp BrdgMode Trans1 Trans2
---- ----- ---------- ----- ------ ------ -------- ---- -------- ------ ------ 1004 fdnet 101004 1500 - - - ieee - 0 0 1005 trbrf 101005 4472 - - 15 ibm - 0 0 VLAN AREHops STEHops Backup CRF ---- ------- ------- ---------- 1003 7 7 off Remote SPAN VLANs
------------------------------------------------------------------------------ Primary Secondary Type Ports ------- --------- ----------------- ------------------------------------------ Switch#show ip int br
Interface IP-Address OK? Method Status Protocol Vlan1 unassigned YES NVRAM up down GigabitEthernet0/1 unassigned YES unset down down GigabitEthernet0/2 unassigned YES unset down down GigabitEthernet0/3 unassigned YES unset up up GigabitEthernet0/4 unassigned YES unset up up GigabitEthernet0/5 unassigned YES unset up up GigabitEthernet0/6 unassigned YES unset up up GigabitEthernet0/7 unassigned YES unset up up GigabitEthernet0/8 unassigned YES unset down down GigabitEthernet0/9 unassigned YES unset down down GigabitEthernet0/10 unassigned YES unset down down GigabitEthernet0/11 unassigned YES unset down down GigabitEthernet0/12 unassigned YES unset down down GigabitEthernet0/13 unassigned YES unset down down GigabitEthernet0/14 unassigned YES unset down down GigabitEthernet0/15 unassigned YES unset down down GigabitEthernet0/16 unassigned YES unset down down GigabitEthernet0/17 unassigned YES unset down down GigabitEthernet0/18 unassigned YES unset down down GigabitEthernet0/19 unassigned YES unset down down GigabitEthernet0/20 unassigned YES unset down down GigabitEthernet0/21 unassigned YES unset down down GigabitEthernet0/22 unassigned YES unset down down GigabitEthernet0/23 unassigned YES unset down down GigabitEthernet0/24 unassigned YES unset down down GigabitEthernet0/25 unassigned YES unset down down GigabitEthernet0/26 unassigned YES unset down down GigabitEthernet0/27 unassigned YES unset down down GigabitEthernet0/28 unassigned YES unset down down Switch# show run Building configuration... Current configuration : 2566 bytes
! version 12.2 no service pad service timestamps debug uptime service timestamps log uptime no service password-encryption ! hostname Switch ! ! no aaa new-model ip subnet-zero ! ! ! ! no file verify auto spanning-tree mode pvst spanning-tree extend system-id ! vlan internal allocation policy ascending ! interface GigabitEthernet0/1 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/2 switchport access vlan 3 switchport mode access duplex full speed 1000 ! interface GigabitEthernet0/3 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/4 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/5 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/6 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/7 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/8 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/9 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/10 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/11 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/12 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/13 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/14 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/15 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/16 switchport access vlan 3 switchport mode access ! interface GigabitEthernet0/17 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/18 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/19 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/20 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/21 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/22 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/23 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/24 switchport access vlan 2 switchport mode access ! interface GigabitEthernet0/25 ! interface GigabitEthernet0/26 ! interface GigabitEthernet0/27 ! interface GigabitEthernet0/28 ! interface Vlan1 no ip address no ip route-cache ! ip http server ! control-plane ! ! line con 0 line vty 0 4 login line vty 5 15 login ! ! end Switch#
Cisco Catalyst 2970系列是业内最全面的可堆叠、独立交换机系列的一个组成部分,这个系列包括Cisco Catalyst 2940、2950、3550和3750系列交换机。思科固定配置交换机为中小型企业和分支机构提供了带智能服务的快速以太网和千兆位以太网配置功能。
Cisco Catalyst 2970G-24TS-24个以太网10/100/1000端口和4个小型可插拔(SFP)端口
Cisco Catalyst 2970G-24T-24个以太网10/100/1000端口 ![]() ![]() SFP是SMALL FORM PLUGGABLE的缩写,可以简单的理解为GBIC的升级版本。SFP模块体积比GBIC模块减少一半,可以在相同的面板上配置多出一倍以上的端口数量。SFP模块的其他功能基本和GBIC一致。有些交换机厂商称SFP模块为小型化GBIC(MINI-GBIC)。 SFP模块体积比GBIC模块减少一半,可以在相同的面板上配置多出一倍以上的端口数量。SFP模块的其他功能基本和GBIC相同。 SFP,SFF,XFP,GBIC,CWDM,DWDM,FWDM,PON光电模块 本文出自 “人类一思考,上帝都发笑” 博客,请务必保留此出处http://3layer.blog.51cto.com/57448/34814 本文出自 51CTO.COM技术博客 |